Compatibility test between flowing aqueous molybdate solution and structural material

In the 99Mo production system with the solution irradiation method, a flowing target solution with a high concentration is in contact with the structural material of the capsule and the pipes, and then it is important to investigate compatibility between the flowing target solution and the structural material. In the previous tests (Inaba et al., 2009), the circulating solution test was carried out under y-ray irradiation. However, the SUS304 specimen used in the test was only immersed in the bottom of an irradiation container with a volume of 2,000 cm3, and the specimen had no influence of the circulating solution flow, and then the compatibility was not cleared. Therefore, the compatibility test between the flowing target solution and the structural material was carried out, and the corrosivity of the flowing target solution for the structural material as well as the chemical stability of the solution was investigated.

An aqueous K2MoO4 solution, which was the first candidate of the irradiation target, was used in the test. The purity of K2MoO4 used in the test was over 98%.