Power measuring channel by fuel and pool temperature

To evaluate the thermal hydraulic performance of the IPR-R1 reactor one instrumented fuel element was put in the core for the experiments. The instrumented fuel is identical to standard fuel elements but it is equipped with three chromel-alumel thermocouples, embedded in the zirconium pin centerline. The sensitive tips of the thermocouples are located one at the center of the fuel section and the other two 25.4 mm above, and 25.4 mm below the center. Figure 18 shows the diagram and design of the instrumented fuel element (Zacarias Mesquita and Cesar Rezende, 2010).

image511

Fig. 18. Diagram of the instrumented fuel element (Zacarias Mesquita and Cesar Rezende, 2010)

The instrumented fuel element which is placed in proper thimble (B6 position) is obvious in Figure 19, a core upper view.

image512

Fig. 19. Core upper view with the instrumented fuel element (Zacarias Mesquita and Cesar Rezende, 2010)

During the experiments it was observed that the temperature difference between fuel element and the pool water below the reactor core (primary loop inlet temperature) do not change for the same power value. Figure 20 compares the reactor power measuring results using the linear neutron channel and the temperature difference channel method (Zacarias Mesquita and Cesar Rezende, 2007).

image513

Fig. 20. Reactor power measured by neutron channel and by fuel element temperature (Zacarias Mesquita and Cesar Rezende, 2007).

There is a good agreement between the two results, although the temperature difference method presents a delay in its response, and it is useful for steady-state or very slow transient. It is notable that the thermal balance method presented in this report is now the standard methodology used for the IPR-R1 TRIGA Reactor power calibration. The heat balance and fuel temperature methods are accurate, but impractical methods for monitoring the instantaneous reactor power level, particularly during transients. For transients the power is monitored by the nuclear detectors, which are calibrated by the thermal balance method (Zacarias Mesquita and Cesar Rezende, 2007).