Mixer-settlers

Mixer-settlers are classed as stage-wise or equilibrium contactors because they manifest a step concentration profile as the aqueous and solvent phases pass from stage to stage. They consist of two compartments (Fig. 3.12): [2]

Contactor

Differential (D) or stage-wise (S)

Reliability

Flexibility

Ease of critically safe design

Size relative to capacity

Comments

Spray column

D

Excellent

Poor

Good

Farge

Packed column

D

Good

Poor

Good

Farge

Rotating disc

D

Poor

Fair

Good

Medium

column

Disk & Donut

D

Excellent

Poor

Good

Medium

In use at Fa Hague,

column Rotary annular

D

Fair

Fair

Good

Medium

France

Proposal only

contactor

Pulsed packed

D

Good

Fair

Good

Medium

Packing tends to

column

Pulsed perforated

D

Excellent

Good

Good

Medium

orientate with pulses

In use at Sellafield, UK

plate column

Reciprocating

D

Poor

Good

Good

Medium

plate column

Raining bucket

D

Fair

Poor

Poor

Farge

Each phase dispersed

contactor

Mixer-settler

S

Excellent

Fair

Poor

Farge

alternately In use at Fa Hague,

Pump-mix

S

Good

Good

Poor

Medium

France and Sellafield UK

mixer-settler

Centrifugal

S

Good

Good

Good

Small

In use at Savannah

contactor Static mixer

S

Excellent

Poor

Good

Small

River USA Proposal only

 

Подпись: © Woodhead Publishing Limited, 2011

image062

Table 3.2 Chemical engineering attributes of mixer-settlers (typical for a used nuclear fuel recycling plant throughput of 5 MTHM/year)

Attribute

Value or description

Dimensions

12 m by 3 m by 2 m

Total liquid volume

60 m3

Total liquid residence time

18 hours

Criticality safety

Not safe by geometry. This restricts mixer-settler application to processing solutions dilute in fissile material.

Design

Well-established using well-proven algorithms. One mixer-settler equivalent to one theoretical stage.

Internal design details include aqueous and solvent weirs, mixed phase port, speed and design of impeller, aqueous off-take weir control system.

Operability

Contactor can be simply restarted without pre-flushing after minor shutdowns. Long residence time provides operators with a long time to respond to process malfunctions.