Analysis of the OSU-MASLWR-001 TRACE calculated data

Starting from the calculated data developed in previous analyses (Pottorf et al., 2009; Mascari et al., 2009b; Mascari et al., 2011c) the target of this section is to give an expanded revised analyses, after a first review of the TRACE nodalization, of the TRACE V5 patch 2 code capability in predicting the primary/containment coupling phenomena typical of the MASLWR prototypical design.

The analysis of the OSU-MASLWR-001 calculated data shows that the TRACE code is able to qualitatively predict the primary/containment coupling phenomena characterizing the test. The blowdown phenomena, the refill of the core and the long term cooling, permitting of removing the decay power, are predicted by the code.

In particular, following the inadvertent middle ADS actuation, the blowdown of the primary system takes place. A subcooled blowdown, characterized by a fast RPV depressurization, is predicted by the code after the SOT.

When the differential pressure in the facility at the break location results in flashing, a two — phase blowdown, qualitatively predicted by the code, occurs. A decrease in depressurization rate of the primary system is then observed, in agreement with the experimental data.

When the PRZ pressure reaches saturation, single phase blowdown occurs and the depressurization rate increases again, in agreement with the experimental data. The RPV and HPC pressure versus code calculations are shown in figure 13.

Fig. 13. Experimental data versus code calculation for PRZ and HPC pressure.

In agreement with the experimental data, when the pressure difference between the RPV and the containment reaches a value less than 0.517 MPa, the high ADS valves are opened which equalizes their pressure.

When the pressure difference reaches a value less than 0.034 MPa, the sump recirculation valves are opened and the refill period begins. The refill phenomenon is predicted by the code. As in the experimental data, the refill period takes place for the higher relative coolant height in the HPC compared to the RPV.

Figure 14 shows the RPV level evolution experimentally detected during the test versus the calculated data. In agreement with the experimental data, the RPV water level never fell below the top of the core. Figure 15 shows the HPC level versus code calculation during the test. The qualitative behavior is well predicted by the TRACE code.

Fig. 14. Experimental data versus code calculation for RPV level.

Fig. 15. Experimental data versus code calculation for HPC level.

In agreement with the experimental data, during the saturated blowdown period the inlet and the outlet temperature of the core are equal each other assuming the saturation temperature value. A core reverse flow and a core coolant boiling off at saturation is predicted by the code. When the refill takes place, the core normal flow direction is restarted. Figure 16 shows the experimental data versus code calculation for outlet core temperature.

In agreement with the experimental data when the sump recirculation valves are opened the vapor produced in the core goes in the upper part of the facility and through the high ADS valve goes to the HPC where it is condensed. At this point through the sump recirculation line and the down comer the fluid goes to the core again (Mascari et al., 2011c, 2011d). Figure 17 shows the long term cooling flow path typical of the MASLWR design.

Figure 18 shows, by using the SNAP animation model capabilities, the fluid condition of facility, 976 s after the SOT, predicted by the TRACE code.

Fig. 16. Experimental data versus code calculation for outlet core temperature.

Fig. 17. Long term cooling flow path typical of the MASLWR design.

Heat Transfer Plate

Fig. 18. SNAP animation model used to analyze the OSU-MASLWR-001 test (976s after the SOT).

From a quantitative point of view the results of the calculated data show a general over prediction compared with the experimental data. It is thought that this could be due to a combination of selection of vent valve discharge coefficients and condensation models applied to the inside surface of the containment (Pottorf et al., 2009; Mascari et al., 2011c).

However, in order to quantitatively evaluate the capacity of the TRACE code to simulate OSU-MASLWR-001 primary/containment coupling phenomena, a qualification of the TRACE nodalization against an heat losses experimental characterization at different primary side temperature is necessary. Figures 19 and 20 show the behavior of PRZ pressure and outlet core temperature respectively by increasing the heat losses of the TRACE model (TRACE_HL). A general quantitative improvement of the calculated data has been showed by TRACE_HL calculation. Therefore in order to quantitatively evaluate the capability of the TRACE code to simulate the OSU-MASLWR phenomena, and therefore use the calculated data for the TRACE code assessment, is necessary a TRACE nodalization qualification against several facility operational characteristics like heat losses at different primary side temperatures and pressure drop at different primary mass flow rate. Currently the TRACE model qualification process is in progress considering the facility characterization that will be disclosed during the current IAEA ICSP.

Fig. 19. Experimental data versus code calculations for PRZ pressure.

Fig. 20. Experimental data versus code calculations for outlet core temperature.

Considering the importance of the containment/reactor vessel thermal hydraulic coupled behavior for the advanced integral-type LWR, in the IAEA ICSP framework a further test, simulating a loss of FW transient with subsequent ADS actuation and long term cooling, will be executed in the OSU-MASLWR facility (Woods & Mascari, 2009; Woods et al.; 2011).

6. Conclusions

The MASLWR is a small modular integral PWR relying on natural circulation during both steady-state and transient operation. During steady state condition the primary fluid, in single-phase natural circulation, removes the core power and transfers it to the secondary fluid through helical coil SG. In transient condition the core decay heat is removed through a passive primary/ containment coupling mitigation strategy based on natural circulation.

The experimental analysis of the primary/ containment coupling phenomena, characterizing the MASLWR design, has been developed in a first testing program at OSU-MASLWR
experimental integral test facility. In particular the OSU-MASLWR-001 test determined the pressure behavior of the RPV and containment following an inadvertent actuation of one middle ADS valve. The test successfully thermal hydraulically demonstrated the passive primary/containment coupling typical of the MASLWR design SBLOCA mitigation strategy.

In the last years the USNRC has developed the advanced best estimate thermal hydraulic system code TRACE in order to simulate operational transients, LOCA, other transients typical of the LWR and to model the thermal hydraulic phenomena taking place in the experimental facilities used to study the steady state and transient behavior of reactor systems. The validation and assessment of the TRACE code against the MASLWR passive primary/containment coupling mitigation strategy is a novel effort and it is the topic of this chapter. Since the qualification process of the OSU-MASLWR TRACE nodalization is still in progress, considering the facility characterization conducted in an IAEA ICSP on "Integral PWR Design Natural Circulation Flow Stability and Thermo-Hydraulic Coupling of Containment and Primary System during Accidents", the current results are preliminary and should not be used for the code assessment, but are able to show the TRACE capability to reproduce the thermal hydraulic phenomena typical of the MASLWR primary/containment coupling SBLOCA mitigation strategy.

The analysis of the OSU-MASLWR-001 calculated data shows that the TRACE code is able to qualitatively predict the primary/containment coupling phenomena characterizing the MASLWR design. The sub-cooled blowdown, two-phase blowdown and single phase blowdown, following the inadvertent middle ADS actuation, are qualitatively predicted by the code. The refill phenomenon is qualitatively predicted by the code as well. In general the results of the calculated data show an over prediction compared with the experimental data. It is thought that this could be due to a combination of selection of vent valve discharge coefficients and condensation models applied to the inside surface of the containment. In agreement with the experimental data, the RPV water level never fell below the top of the core. However, in order to quantitatively evaluate the capability of the TRACE code to simulate the OSU-MASLWR phenomena, and therefore use the calculated data for the TRACE code assessment, is necessary a TRACE nodalization qualification against several facility operational characteristics like pressure drop at different primary mass flow rates and heat losses at different primary side temperatures. Currently the TRACE model qualification process is in progress considering the facility characterization conducted during the IAEA ICSP.

7. Abbreviations

ADS

AP600/1000 CAREM CHF CL CPV EHRS ESBWR FW

Total energy; Gravitational force; Pressure; Temperature;

Phase velocity.

9. Greek symbols

a

Vapor void fraction;

Гк

Mass generation rate per unit volume;

P

Density.

10.