14C-MeOH

The results from the analysis of 14C-MeOH are not consistent with nominal values in most cases (Table 23). Some of the participants reported that they could not find any 14C-MeOH in any of the samples while others reported a low concentration of 14C-MeOH in comparison with the nominal value for some samples. Some laboratories did not apply the enrichment process (distillation) to measure low concentrations of 14C-MeOH while others attempted to distill samples but still found zero or low concentrations.

The results reported from Vietnam are acceptable. Measurements were carried out soon after receipt of the samples, on 21 January 2008. Upon receipt of various comments from participating laboratories regarding the difficulties of measuring 14C-MeOH in the samples, CANTI’s tracer laboratory was requested to measure a stored reference set of samples (29 June 2008). The new analysis showed the same difficulty or problem previously observed and reported by the other laboratories. There was close to zero activity of 14C in the stored samples (Table 24).

TABLE 22. ANALYTICAL RESULTS OF НТО FROM PARTICIPATING LABORATORIES

No.

Prep. cone. ±la (Bq/L)

Measured concentration ±la (Bq/L)

Argentina

Brazil

China

France

Indonesia

Norway

Pakistan

Vietnam

A1

0.0

0.6 ±4.5

<3 + 2.1

251+6.1

2.0 ±0.1

6.2

<2

0 + 3.8

0.0

A2

14.8+0.7

15.4 + 4.7

7.2 ±2.5

288 ±7.0

15.8 ± 0.5

18.1

17+1.0

12.4 + 5.7

11.1+0.7

A3

14.8+0.7

19.8 + 4.8

7.2 ±2.4

275 ±6.7

15.8 ± 0.5

17.1

14 + 1.0

9.2 ±5.5

14.0 + 0.9

A4

0.0

1.3 ± 4.5

<3 + 2.2

249 + 6.0

2.0 ±0.1

11.0

<2

0.0 ±2.9

1.3±0.1

2A5

148 + 7

155 ±6.3

140.8 + 8.5

453+ 10

154 + 3.0

122

132 ±3.0

139.7 + 8.1

135 ±5.2

A6

0.0

6.3 ±4.6

<3 + 2.1

229 ±5.6

<2

16.7

<2

0.0 ±3.2

0.0

A7

592 +30

57 + 59.5

568 ±26

1110 ± 26

597 + 8.0

490

649 ± 7.0

622.8+ 18.9

558 ± 12

A8

14.8+0.7

17.3 + 4.7

8.2 ±2.6

276 ±6.7

13.8 ±0.2

19.2

14 ± 1.0

0.0 ±3.3

16.8± 1.1

A9

148 + 7

157 ± 0.3

145 + 7.5

428 + 9.7

142 ±0.3

131

165 ±3.0

142.1 + 8.9

138 ±5.5

A10

14.8 + 0.7

17.9 ±4.7

15.7 + 2.4

242 + 6.1

11.0+2.0

32.5

18+1.0

12.6 + 6.1

10.4 + 0.6

All

592 ± 30

582 ±9.5

600 ± 28

998 ±25

583 + 8.0

497

647 ± 7.0

645.1 ± 19.9

551 ± 12

A12

148 + 7

160 + 6.3

142 ± 8.0

477 ± 11

150 ±3.0

126

165 + 3.0

148.5 ±8.4

134 + 4.9

A13

592 ± 30

598 + 9.6

588 ±28

1060 ±5.5

600 ± 8.0

497

660 ± 7.0

651.9 ± 20.5

550 ± 12

A14

148 + 7

159 ±6.3

144 ±8.2

433 + 9.7

140 ±3.0

135

167 ±3.0

148.5 ±8.3

132 ±4.9

A15

592 ± 30

568.3 ±9.4

586 + 29

1010 + 23

600 ± 8.0

504

641 ±6.0

613.1 ± 19.7

543 ± 12

Bq/L

о S Й

image165

 

image166

іґ>

и

I

І

5

о

 

image167

 

3-

 

image168image169

image170image171image172image173image174image175image176image177

image178

FIG. 84. Radar plot representation of the datasets.

TABLE 23. ANALYTICAL RESULTS OF 14C-MEOH FROM PARTICIPATING LABORATORIES

No.

Prepared conc. ±1a (Bq/L)

Measured concentration ±1a (Bq/L)

Brazil

France

Norway

Vietnam

A2

0.74 + 0.4

n. d. ±1.4

<0.005

0.78 ± 0.23

A3

0.0

0.8a ± 1.5

<0.005

0.32

A4

7.4 + 0.4

2.9a ± 1.6

<0.005

6.20 ± 0.46

A5

0.0

n. d. ± 1.6

<0.005

0.21

A6

74 + 4

6.95 ± 0.44

37.8 ± 0.40

32 ± 1.5

76.92 ± 4.92

A7

0.0

0.9a ± 1.5

<0.005

0.12

A8

7.4 + 0.4

n. d. ± 1.6

0.46 ± 0.01

8.95 ± 0.68

A9

0.74 + 0.04

n. d. ± 1.4

<0.005

32 ± 1.5

0.94 ± 0.15

A10

74 + 4

n. d. ± 1.5

46.9 ± 0.50

65.44 ± 5.17

A11

0.74 + 0.04

0.4a ± 1.5

<0.005

0.81 ± 0.13

A12

7.4 + 0.4

n. d. ± 1.4

0.21 ± 0.01

6.08 ± 0.82

A13

7.4 + 0.4

n. d. ± 1.5

<0.005

8.26 ± 1.10

A14

74 + 4

1.0a ± 1.4

22.75 ± 0.33

14.5 ± 1.2

71.37 ± 3.75

A15

74 + 4

0.2a ± 1.4

18.11 ± 0.31

18 ± 1.2

± 6.85

a Values below detection limit.

TABLE 24. ANALYTICAL RESULTS FROM TRACER LABORATORY (CANTI) FOR TWO DIFFERENT MEASUREMENTS

No.

Prepared conc. 14C-MeOH concentration (Bq/L) 14C-MeOH concentration (Bq/L) (Bq/L) (Measured 21-25 January 2008 (Measured 29 June to 4 July 2008 Glass bottles. Distillation PE bottles. Distillation procedure procedure applied) applied)

A1

0.74

0.94

0

A2

0.74

0.68

0

A3

0

0

0

TABLE 24. ANALYTICAL RESULTS FROM TRACER LABORATORY (CANTI) FOR TWO DIFFERENT MEASUREMENTS (cont.)

No. Prepared conc. 14C-MeOH concentration (Bq/L) 14C-MeOH concentration (Bq/L)

(Bq/L)

(Measured 21-25 January 2008 Glass bottles. Distillation procedure applied)

(Measured 29 June to 4 July 2008 PE bottles. Distillation procedure applied)

A4

7.4

6.20

0

A5

0

0

0

A6

74.0

76.92

0.92

A7

0

0

0

A8

7.4

8.95

0

A9

0.74

1.08

0

A10

74

65.44

0.2

A11

0.74

0.81

0

A12

7.4

6.08

0

A13

7.4

8.26

0

A14

74.0

53.52

0.77

A15

74.0

91.39

0.51

TABLE 25. ORIGINAL STANDARD SOLUTIONS OF HTO AND 14C-MEOH

Original standard

Supplier

Model/lot number

Solvent

Concentration

(Bq/mL)

Calibration date

HTO

ARC

ART 0194A /Lot: 070427

Water

3.7E7 + 1%

13 August 2007

14C-MeOH

ARC

ART 0194A /Lot: 070305

MeOH

3.7E6 + 1%

19 February 2007