Tracers and tracer injection

As indicated in Fig. 77, three radioactive tracers were used in the test, HTO, 14C tagged KSCN and 60Co tagged K3[Co(CN)6]. In the test, 20 mCi of 14C tagged KSCN was injected into well 20-2 on 10 July 2005, and 10 Ci of HTO, together with 25 mCi of 60Co tagged K3[Co(CN)6], was injected into well 21-3 on 11 July 2005.

1.6.2. Tracer responses

All tracers were detected in corresponding production wells:

• The 14C from well 20-2 was found on 30 January 2006 at well 12-3, 204 d after injection.

• The HTO from well 21-3 was found on 30 November 2005 at well 13-4, 141 d after injection, and was found on 23 January 2006 at well 13, 195 d after injection.

• The 60Co from well 21-3 was found on 05 January 2006 at well 13-4, 177 d after injection.

Tracer injection and directional tracer movements are shown in Fig. 78.

Подпись: C-14 of Well 20-2 Response at Well 12-3 Days after Tracer Injection FIG. 79. Carbon-14 of well 20-2 response at well 12-3.

PORO software simulation was used for tracer data treatment. Tracer response curves are shown in Figs 79 and 80.

Подпись: FIG. 80. HTO and 60Co of well 21-3 response at well 13-4.

141 192 222 243 266 286 304 324 342 364 398 454 524 573 674
Days after Tracer Injection

Appendix II