Operating conditions

Table 3 lists operating conditions. Permeate flux was incremented from 20 to 35 l/(hm2) in successive experimental runs. In order to maintain a constant HRT independent from the imposed permeated flux in each run, a peristaltic pump extracted from the permeate tank the flow rate necessary to maintain the required HRT and the excess of permeate was returned to the bioreactor (see Figure 1). Chemical cleaning of the membrane with sodium hypochloride (250 mg/l) was performed at the end of each experimental run.

Air was supplied through the bottom providing oxygen and stirring. The dissolved oxygen concentration was always above 1.5 mg/l in the reactor operated at 23 ± 2 °С.

1.4 Analytical methods

Dissolved oxygen (DO) was measured using a WTW 340i. Chemical oxygen demand (COD), ammonium-nitrogen (N-NH+), total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS) were determined in conformity with the Standard Methods (American Public Health Association, 1992). Nitrite-nitrogen (N — NO2-) and Nitrate-nitrogen (N-NO3-) were measured by spectrophotometric methods with a HACH DR 2000. Microbial floc size was measured by Coulter LS100 (Coulter, UK). Proteins were determined as bovine albumin equivalent using the protein kit assay TP0300 supplied by Sigma, following the Lowry method (Lowry et al., 1951). Polysaccharides were measured as glucose equivalent by the Dubois’ method (Dubois et al., 1956).

Parameters

Units

Value

Sludge retention time (SRT)

days

Infinite (without purge)

Hydraulic retention time (HRT)

hours

24.6

Filtration time

seconds

450

Duration of relax phase

seconds

30

Aeration rate per membrane area (SADm)

Nm3/h m2

1.9

Permeate flux

l/h m2

20-35

Table 3. Operating conditions of the pilot-scale MBR

The oxygen uptake rate was measured by following the dissolved concentration with a membrane oxygen electrode in a medium without substrate (SOURe, endogenous). The sludge rheological properties were determined by using the concentric cylinder rotational viscosimeter Visco Star plus (FungiLab, Spain). The width of the annular gap was 1.0 mm. Measurements were done at 25 °C.