Estimation of spectral characteristics of the stand

The imaging set consisted of a multispectral camera DuncanTech MS-3100 (manufacturer Geospatial Systems, Inc., USA) with the objective Sigma 14 mm F2.8 Aspherical HSM, a notebook Acer Aspire 1362 (AMD Sempron 2800+, 512MB RAM, 60GB HD), and a framegrabber (videograbber) National Instruments NI-1428, which was connected with the notebook via PCMCIA and communicated with the camera via a CameraLink interface. Power for the whole set was supplied from a portable 42 Ah accumulator with a 12V/220V changer (transformer). The camera was controlled via a COM interface and the recording of images was performed in DTcontrol software. Because of a problematic connectivity with the framegrabber the notebook was later on replaced by a desktop PC (Intel Pentium II 400 Mhz, 640 MB RAM, 40 GB HDD) with a framegrabber placed in the PCI slot and with a 17" LCD monitor.

The imaging part of the camera consisted of three CCD elements with filters of the size 7.6 x 6.2 mm, which recorded in three bands of electromagnetic radiation — green (500-600 nm, peak 550 nm), red (600-700 nm, peak 650 nm) and near infrared (750-900 nm, peak 830 nm).

image008By composing 8 bit images from CCD the so-called CIR (colour infrared) the image was obtained in false colours with the size of 1,392 x 1,039 pixels, and this was subsequently stored in a wireless TIFF format. The use of a wide (14 mm) objective enabled to reach (in combination with the physical size of the CCD element) a wide angle of recording (ca 26° x 20°).

For imaging from the height of 5.5 m, a mobile aluminium scaffold was used (Figure 4); this corresponded with the image area 2.54 x 1.9 m (4.83 m2) and the spatial resolution of less than 2 mm per pixel. Since 2005, a set of optic etalons SphereOptics Zenith® was a part of each imaged scene to normalize the reflectance of radiation in accordance with existing light conditions. This set consisted of four polytetrafluorethylene (PTFE) etalons with exactly calibrated reflectances of 10 %, 25 %, 50 %, and 70 %. Used material had the so-called Lambert perfectly diffusing surface for which the intensity of reflected radiation was independent of direction of radiation incidence. From the viewpoint of field measurements resistance and washability of polytetrafluorethylene were also advantageous.

MS 3100

CameraLink

+ COM + 12V

cables

12V/220V

changer

acumulator

framegrabber

laptop

area of interest

Figure 4. A view of imaging equipment

When processing recorded images, a radiometric correction was performed at first to eliminate differences in light conditions of imaging (sunny — overcast), i. e. to normalize
reflectance. The normalization of images to constant light conditions was performed on the basis of a conversion of digital numbers (DN) of image pixels according to the measured and calibrated reflectance of a 25 % optic etalon. Using images processed in this way it was thereafter possible to calculate the Normalized Difference Vegetation Index (NDVI) according to the equation NDVI = (NIR — R)/(NIR + R). Simultaneously, average values of DN and NDVI of the demarcated part of the canopy were determined on the basis of CIR and NDVI images (NIR = Near Infrared, R = Red, CIR = Colour Infrared).