Charging processes

During the charging process, as no fluid flows through the absorber, the calculated absorber temperature is directly linked to the composite temperature at the interface by:

— к

Подпись:

c

Подпись:

К / a (Tc — T )

Подпись: (eq.12)

Fig.5: Comparison between experience (interface absorber/polymer (o), interface PCM/polymer (A) and polymer (□) temperature) and simulation (interface absorber/polymer (—) and polymer (—) temperature) in charging

process

Подпись: Fig.5: Comparison between experience (interface absorber/polymer (o), interface PCM/polymer (A) and polymer (□) temperature) and simulation (interface absorber/polymer (—) and polymer (—) temperature) in charging process

With an exchange coefficient of 130 W. m-2.K-1 we obtain the temperature profile plotted in figure 5. The simulated temperature profile at the middle of the composite is situated between the two recorded experimental temperatures.